Is an adequate number of accessible parking spaces available?
No
Measurements
0
View photos
No photos are attached
Is there an enforcement procedure to ensure that accessible parking is used only by those who need it?
No
Measurements
View photos
No photos are attached
Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No
Measurements
View photos
No photos are attached
Is the route at least 0.9 m in width?
Yes
Measurements
View photos
No photos are attached
Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
No
Measurements
not calculated yet
View photos
No photos are attached
Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No
Measurements
View photos
No photos are attached
Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
Yes
Measurements
1:12
View photos
No photos are attached
Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes
Measurements
View photos
No photos are attached
Are all ramps longer than 2 meters have railings on both sides?
No
Measurements
View photos
No photos are attached
Is the width between railings or curbs at least 0.9 meters?
Yes
Measurements
1:20
View photos
No photos are attached
Are the railings sturdy and between 0.84 and 1 meters in height?
Yes
Measurements
1 m ارتفاعه
View photos
No photos are attached
If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes
Measurements
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes
Measurements
0.95
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes
Measurements
1 m
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
90 cm
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
Yes
Measurements
not calculated yet
View photos
No photos are attached
General text description:
يوجد منحدر من الشارع للرصيف و منحدر اخر من الرصيف للمدخل و هو طويل لكنه مطابق للمواصفات ولكن لا يوجد درابزين على كلتا الجهتين و لا يوجد لافتات و المنحدر الوحيد الذي يصل بين الشارع و الرصيف ولكن تعيقه السيارات امامه
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
View photos
No photos are attached
Are all public spaces have an accessible route of travel?
No
Measurements
View photos
No photos are attached
Is the accessible route to all public spaces at least 0.9 meters wide?
Yes
Measurements
1 m
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes
Measurements
2m
View photos
No photos are attached
Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes
Measurements
0.95
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
No
Measurements
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
90 cm
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes
Measurements
6 m
View photos
No photos are attached
In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes
Measurements
View photos
No photos are attached
2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes
Measurements
View photos
No photos are attached
Are signs mounted with Centerline 1.53 meters from the floor?
No
Measurements
1:40
View photos
No photos are attached
are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes
Measurements
View photos
No photos are attached
Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No
Measurements
not calculated yet
View photos
No photos are attached
Is the text of the sign brailed of the same information?
No
Measurements
View photos
No photos are attached
If a pictogram is used is it accompanied by raised characters and braille?
No
Measurements
View photos
No photos are attached
Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes
Measurements
70 cm
View photos
No photos are attached
Are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
Are the spaces for wheelchair distributed throughout?
No
Measurements
View photos
No photos are attached
On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes
Measurements
View photos
No photos are attached
Are there ramps, lifts or elevators to all public levels?
Yes
Measurements
View photos
No photos are attached
Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
No
Measurements
View photos
No photos are attached
Are the call buttons in the hallway no higher than 1 meters?
Yes
Measurements
90 cm
View photos
No photos are attached
Do controls inside the cab have raised and braille lettering?
Yes
Measurements
View photos
No photos are attached
Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No
Measurements
View photos
No photos are attached
General text description:
"الخدمات غير متاحة دائما بحيث ان استخدام دورات المياه يتطلب منك ان تسأل موظف الاستقبال حتى يعطيك المفتاح
ولكن المتبقي بأمكان ذوي الاحتياجات الخاصة ان يخدم نفسه و يفتح الابواب و يستعمل المصعد"
Is the doorway at least 0.9 meters clear?
Yes
Measurements
95 cm
View photos
No photos are attached
Are doors equipped with accessible handles (operable with closed fist), 1-meter high?
Yes
Measurements
1 m
View photos
No photos are attached
Can doors be opened easily (operable with closed fist)?
Yes
Measurements
View photos
No photos are attached
Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
Yes
Measurements
2 m
View photos
No photos are attached
General text description:
غرف الحمام غير متاحة للعامة ولكن يجب طلب استعمالها من قبل الادارة و لكن مساحتها اكثر من 1.5 م فيمكن الدخول بسهولة
Customers Comments