H.Manaseer Training and Consulting Cente


Overview

JUST-Able Evaluation  

Is an adequate number of accessible parking spaces available?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes


Is the route at least 0.9 m in width?
Yes


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


General text description:
"لا يوجد مواقف مخصصه للعامة ولذوي الإعاقة ،ليست جميع لأرصفة امام المجمع متصله مع سطح الطريق . المنحدر غير مستقر وغير ثابت وغير مقاوم للإنزلاق ولا يحتوي أي بروزات يمكن تمييزها بالعصا البيضاء،لا يوجد درابزين حمايه و المنحدر حاد جداً و اقل من نسبة 1:10- 1:12 بفارق كبير و يحتاج للشخص الذي يستخدم الكرسي المتحرك مساعدة شخص آخر لتخطيها ، لا يوجد لافتات خاصة تدل على اقرب مدخل لذوي الإعاقة ،عرض مدخل الباب الرئيس واسع ويمكن تمييزه عن واجهة البناء ويمكن فتحه بقبضة اليد المغلقه ويوجد مساحة جانبية فارغه تزيد عن متر لكن يوجد عتبة تزيد عن 2سم ."

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
Yes


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


If emergency systems are provided, do they have both flashing lights and audible signals?
Yes


Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes


Are they operable with a closed fist?
Yes


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes


Are the spaces for wheelchair distributed throughout?
Yes


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes


At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes


Is there a portion of for ordering counters that is no more than 0.9 meters high, or is there space at the side for passing items to customers who have difficulty reaching over a high counter?
Yes


On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes


If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes


If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
Yes


Are there ramps, lifts or elevators to all public levels?
Yes


Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
No


Are the call buttons in the hallway no higher than 1 meters?
No


Do controls inside the cab have raised and braille lettering?
No


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


General text description:
"الممر الداخلي يوفر وصولاً مباشراً للمصعد ،ويوجد مساحة دائرية وجانبية فارغه وكافية للتنقل والالتفاف بسهولة من خلالها الالتف، باب المصعد ضيق للحركة على الكرسي المتحرك و عرض الباب 80 سم ويوجد عتبه عند باب المصعد تقدر ب 2سم ،لا يوجد داخل المصعد ازرار بلغة بريل ولا يوجد تنبيهات صوتية. يوجد درج ذو مساحة عرضيه واسعة مع درابزين حماية لطابق الأكاديمية ، بلاط الدرج مقاوم للإنزلاق وسلس ومرن للحركه والتنقل ويمكن تمييز حوافه بالعصا البيضاء ،ولا يوجد لافتات مرئية داخل الأكاديمية ، والممرات الداخلية بين الطاولات واسعة ويمكن التنقل من خلالها بسهولة . داخل الغرفه الصفيه يوجد مساحة مخصصه للكراسي المتحركة . الاضاءة داخل الأكاديمية لونها معتدل ومساوي للإضاءة الخارجية ،يوجد مقابس كهرباء بجانب الطاولات يمكن تشغيليها بقبضة اليد وارتفاعها 70 سم . وارتفاع الطاولات مناسب وعمق الطاولات مناسب ايضا ، يوجد طاولة محاسبه ارتفاعها مهيء ومناسبة لتبادل الدفع من خلالها ،ويوجد خدمة دفع متنقله الكترونيه."

If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No


Are there signs at inaccessible rest rooms that give directions to accessible ones?
No


Is the doorway at least 0.9 meters clear?
Yes


Are doors equipped with accessible handles (operable with closed fist), 1-meter high?
Yes


Can doors be opened easily (operable with closed fist)?
Yes


Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
No


Is there a sign for restrooms that can be touched?
No


In the accessible stall are there grab bars behind and on the side wall nearest to the toilet?
No


Is the toilet seat 0.43 to 0.48 meters high?
Yes


Is the toilet seat supported with a built-in bidet or does it have a handheld bidet?
Yes


Is the mirror mounted with the bottom edges of the reflecting surface 1.02 meters high or lower?
Yes


General text description:
بالنسبة للوحدة الصحية: لا يوجد حمامات مخصصه لذوي الإعاقه وانما هي وحدة صحية للعامة وواحد لكلا الجنسين،لا يوجد لافتات خاصه بالوحدات الصحية ، المساحة الداخلية للحمام ضيقه بعض الشيئ لذوي الإعاقة الحركية فلا تسمح للأشخاص الالتفاف والتحرك بسهولة،،يمكن فتح باب المدخل بقبضه اليد المغلقه.

General text description:

Customer Reviews

5

(1 Rating)

Customers Comments

19-01-2023 02:27:34 PM

hzhshs

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able