Is an adequate number of accessible parking spaces available?
No
Measurements
View photos
No photos are attached
Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
View photos
No photos are attached
Is the route at least 0.9 m in width?
Yes
Measurements
الطريق واسع
View photos
No photos are attached
Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes
Measurements
View photos
No photos are attached
Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
View photos
No photos are attached
Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
Yes
Measurements
طول الرامب 2.20 م ارتفاع الرصيف 20 سم
View photos
No photos are attached
Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes
Measurements
View photos
No photos are attached
Are all ramps longer than 2 meters have railings on both sides?
No
Measurements
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes
Measurements
العرض 1م
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes
Measurements
View photos
No photos are attached
Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
Yes
Measurements
لا يوجد عتبة
View photos
No photos are attached
If the door has a closer does it take at least 3 seconds to close?
Yes
Measurements
View photos
No photos are attached
General text description:
يوجد أمام المبنى مصفات عامة أقرب ما يكون إلى المدخل وهناك رمبات وأطراف متصلة ما بين الشارع والمدخل تحقق الوصولية وهناك في المبنى باب فرعي مزود برامبا من الشارع وسعت مدخله جيدة بضمنك وصولية جيدة
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
View photos
No photos are attached
Are all public spaces have an accessible route of travel?
Yes
Measurements
View photos
No photos are attached
Is the accessible route to all public spaces at least 0.9 meters wide?
Yes
Measurements
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes
Measurements
View photos
No photos are attached
2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes
Measurements
عرض الممرات يتراوح بين 1.20_2 م
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes
Measurements
View photos
No photos are attached
In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes
Measurements
View photos
No photos are attached
2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes
Measurements
View photos
No photos are attached
If emergency systems are provided, do they have both flashing lights and audible signals?
Yes
Measurements
View photos
No photos are attached
Are signs mounted with Centerline 1.53 meters from the floor?
Yes
Measurements
ارتفاع اللافتات 1.5م
View photos
No photos are attached
are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes
Measurements
View photos
No photos are attached
Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
Yes
Measurements
View photos
No photos are attached
Is the text of the sign brailed of the same information?
No
Measurements
View photos
No photos are attached
If a pictogram is used is it accompanied by raised characters and braille?
No
Measurements
View photos
No photos are attached
Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes
Measurements
مثلا أبواب الثلاجات ارتفاع مقبضها 1.10م
View photos
No photos are attached
Are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes
Measurements
View photos
No photos are attached
Are the spaces for wheelchair distributed throughout?
Yes
Measurements
View photos
No photos are attached
Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes
Measurements
ارتفاع الطاولات 0.75م
View photos
No photos are attached
Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes
Measurements
ارتفاعها 75سم عرضها 75سم عمققها 73سم
View photos
No photos are attached
At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes
Measurements
ارتفاعها ?م
View photos
No photos are attached
Is there a portion of for ordering counters that is no more than 0.9 meters high, or is there space at the side for passing items to customers who have difficulty reaching over a high counter?
Yes
Measurements
View photos
No photos are attached
On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
Yes
Measurements
View photos
No photos are attached
Are there ramps, lifts or elevators to all public levels?
Yes
Measurements
View photos
No photos are attached
Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
Yes
Measurements
View photos
No photos are attached
Are the call buttons in the hallway no higher than 1 meters?
No
Measurements
ارتفاع الازرار 1.20م
View photos
No photos are attached
Do controls inside the cab have raised and braille lettering?
Yes
Measurements
View photos
No photos are attached
Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No
Measurements
View photos
No photos are attached
Is the emergency intercom identified by braille and raised letters?
No
Measurements
View photos
No photos are attached
General text description:
الممرات داخل المبنى واسعة وهناك مساحات كافية الدوران وسهولة الحركة والاضائة داخل المبنى ملائمة وهناك مصاعد داخل المبنى توفر وصولية لكل الطوابق وهناك نوافذ للخدمة بارتفاعات مناسبة حتى صالة الألعاب يمكن دخولها من قبل ذوي الإعاقة الحركية لكن الخدمات داخل المبنى ينقصها بعض التهيئة لذوي الإعاقة البصرية كذلك الممرات والدرج ينقصها ببروزات أرضية لارشادهم
If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No
Measurements
View photos
No photos are attached
General text description:
If there is an ATM machine, Does the height and depth follow the following requirements in cm:
Yes
Measurements
View photos
No photos are attached
4.1.2. Is the ATM machine have a verbal or audible sound system? Do controls have raised and braille lettering?
Customers Comments