Is an adequate number of accessible parking spaces available?
No
Measurements
لا يوجد
View photos
No photos are attached
Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No
Measurements
View photos
No photos are attached
Is the route at least 0.9 m in width?
Yes
Measurements
عرض المنحدر المخصص للاشخاص ذوي الاعاقة 1.75 م
View photos
No photos are attached
Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes
Measurements
View photos
No photos are attached
Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
View photos
No photos are attached
Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
Yes
Measurements
طول المنحدر 41.5 م / ويرتفع الى منسوب 3.12 م من مستوى سطح الارض
View photos
No photos are attached
Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes
Measurements
View photos
No photos are attached
Are all ramps longer than 2 meters have railings on both sides?
No
Measurements
View photos
No photos are attached
Are the railings sturdy and between 0.84 and 1 meters in height?
Yes
Measurements
ارتفاع الدرابزين 0.95 م
View photos
No photos are attached
Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
No
Measurements
عرض البسطة مساوي لعرض المنحدر 1.75 م وبطول يزيد عن 2 م
View photos
No photos are attached
If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes
Measurements
View photos
No photos are attached
Do all inaccessible entrances have signs indicating the location of the nearest accessible entrance?
No
Measurements
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
No
Measurements
عرض فتحة المدخل الرئيسي 0.63 م
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes
Measurements
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
View photos
No photos are attached
General text description:
"تحقق مكتبة الحسين بن طلال في جامعة اليرموك وصولية جيدة في مستويات متعددة الا ان هناك معيقات للوصولية الى المداخل الرئيسية منها :
# لا يوجد مواقف مخصصه للاشخاص ذوي الاعاقه، و لكن يوجد موقف قريب لمدخل المكتبة
# يوجد اتصال مباشر بين ارصفة المشاة و مستوى سطح الطريق ، الا انه قد تعيق الوصولية اصطفاف المركبات في الاماكن التي تسمح بهذه الوصولية المباشره.
# طريق المشاة مستقر، ثابت، مقاوم للإنزلاق ولكن لا يوجد بلاط بلون فاقع او مزود ببروز يمكن استشعاره بالعصي.
# يوجد منحدر يؤدي الى المدخل الرئيسي للمكتبة ويحقق نسبة وصولية ممتازة ولكن يوجد له درابزين من جانب واحد .
#عرض الباب الرئيسي ضيق بعض الشيء و لكن الباب مفتوح غالبا خلال اوقات الدوام ."
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
View photos
No photos are attached
Are all public spaces have an accessible route of travel?
No
Measurements
View photos
No photos are attached
Is the accessible route to all public spaces at least 0.9 meters wide?
Yes
Measurements
توجد مساحات مفتوحة وممرات بابعاد تزيد عن 0.90 م
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes
Measurements
View photos
No photos are attached
Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes
Measurements
متوسط عرض الابواب داخل المكتبة في الغالب من 1.10 م الى 1.30 م
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
Yes
Measurements
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
ارتفاع مقبض الباب 0.73 م
View photos
No photos are attached
2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes
Measurements
تزيد الممرات عن 0.90 م في الغالب
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes
Measurements
View photos
No photos are attached
In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes
Measurements
View photos
No photos are attached
2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes
Measurements
View photos
No photos are attached
If emergency systems are provided, do they have both flashing lights and audible signals?
Yes
Measurements
View photos
No photos are attached
Are signs mounted with Centerline 1.53 meters from the floor?
Yes
Measurements
View photos
No photos are attached
are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes
Measurements
View photos
No photos are attached
Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No
Measurements
View photos
No photos are attached
Is the text of the sign brailed of the same information?
No
Measurements
View photos
No photos are attached
Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes
Measurements
توجد مقابس الكهرباء بارتفاعات متعددة جميعها تزيد عن 0.38 م / وبارتفاع اقل من 1.37 م .
View photos
No photos are attached
Are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes
Measurements
تزيد عن 0.90 م الى اكبر من 2 م
View photos
No photos are attached
Are the spaces for wheelchair distributed throughout?
Yes
Measurements
View photos
No photos are attached
Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes
Measurements
ارتفاع الطاولات 0.77 م
View photos
No photos are attached
Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes
Measurements
ارتفاع الفارغ اسفل الطاولات 0.74 م وبعمق مفتوح على عرض الطاولة 1 م .
View photos
No photos are attached
At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes
Measurements
ارتفاعها 0.75 م
View photos
No photos are attached
Is there a portion of for ordering counters that is no more than 0.9 meters high, or is there space at the side for passing items to customers who have difficulty reaching over a high counter?
Yes
Measurements
ارتفاعها 0.75 م
View photos
No photos are attached
On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
Yes
Measurements
View photos
No photos are attached
Are there ramps, lifts or elevators to all public levels?
Yes
Measurements
View photos
No photos are attached
Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
Yes
Measurements
View photos
No photos are attached
Are the call buttons in the hallway no higher than 1 meters?
No
Measurements
ارتفاع ازرار المصعد يبدأ من 1.20 م ويزيد .
View photos
No photos are attached
Do controls inside the cab have raised and braille lettering?
Yes
Measurements
View photos
No photos are attached
Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No
Measurements
View photos
No photos are attached
Is the emergency intercom identified by braille and raised letters?
No
Measurements
View photos
No photos are attached
General text description:
"تحق مكتبة الحسين بن طلال وصولية الخدمات بمستوى جيد الا انه يوجد بعض المعيقات يمكن ايجازها ب :
# يمكن التحرك داخل المكتبة من ذوي الاعاقة الحركية ولكن لم يتم تأهيلها لخدمة ذوي الاعاقة البصرية ( لا يوجد بلاط مزود بتباين عالي و ببروز يمكن استشعاره بالعصي ).
# لا تحتوي اللافتات على احرف بارزة او احرف بلغة برايل وكذلك لا يوجد رسم تخطيطي فيها
# يوجد مصاعد تؤدي الى مختلف الخدمات في المكتبة من الطابق الارضي لجميع الخدمات ما عدا قاعات الدراسة الجماعية وتوجد فيه مؤشرات ضؤية ولكن لا يوجد مؤثرات صوتية وكذلك ارتفاع الازرار في المصعد مرتفع بعض الشيء
# تحقق الممرات في الغالب عرض مناسب لذوي الإعاقة الحركية"
If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No
Measurements
View photos
No photos are attached
General text description:
لا يوجد وحدة صحية مؤهلة لخدمة الاشخاص ذوي الاعاقة و مساحتها ضيقة للحركة
General text description:
لا يوجد جهاز صراف الي داخل المكتبة، ولكن يمكن الاستفادة من التي تنتشر في اماكن أخرى من جامعة اليرموك مثل: صراف بنك الاسكان مقابل كلية التربية وصراف بنك القاهرة عمان في مبنى الأمن الجامعي .
Customers Comments