Is an adequate number of accessible parking spaces available?
No
Measurements
View photos
No photos are attached
Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
View photos
No photos are attached
Is the route at least 0.9 m in width?
Yes
Measurements
View photos
No photos are attached
Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes
Measurements
View photos
No photos are attached
Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
View photos
No photos are attached
Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No
Measurements
0.50 - 1
View photos
No photos are attached
Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes
Measurements
View photos
No photos are attached
Are all ramps longer than 2 meters have railings on both sides?
No
Measurements
View photos
No photos are attached
Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
Yes
Measurements
7 m
View photos
No photos are attached
If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
No
Measurements
View photos
No photos are attached
Do all inaccessible entrances have signs indicating the location of the nearest accessible entrance?
No
Measurements
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes
Measurements
87cm
View photos
No photos are attached
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes
Measurements
1.7
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
50 cm
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
Yes
Measurements
View photos
No photos are attached
If the door has a closer does it take at least 3 seconds to close?
Yes
Measurements
? ثواني
View photos
No photos are attached
General text description:
جيدة ويمكن الوصول الى المدخل بسهولة بسبب المساحات الكبيرة
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
View photos
No photos are attached
Are all public spaces have an accessible route of travel?
No
Measurements
View photos
No photos are attached
Is the accessible route to all public spaces at least 0.9 meters wide?
Yes
Measurements
2.5
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes
Measurements
1.5
View photos
No photos are attached
Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes
Measurements
95 cm
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
No
Measurements
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
1 m
View photos
No photos are attached
Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No
Measurements
5 cm
View photos
No photos are attached
Are signs mounted with Centerline 1.53 meters from the floor?
No
Measurements
View photos
No photos are attached
On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
No
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
No
Measurements
View photos
No photos are attached
Are there ramps, lifts or elevators to all public levels?
Yes
Measurements
View photos
No photos are attached
Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
Yes
Measurements
View photos
No photos are attached
Are the call buttons in the hallway no higher than 1 meters?
No
Measurements
1.1
View photos
No photos are attached
Do controls inside the cab have raised and braille lettering?
Yes
Measurements
View photos
No photos are attached
Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
Yes
Measurements
View photos
No photos are attached
General text description:
من السهل الدخول عبر المدخل والوصول الى المصعد ولكن وجي الحذر بالمصعد بسبب طبيعة الارضية
Customers Comments