Liwan Space


Overview

JUST-Able Evaluation  

Is the car parking 2.5 meters in width plus 1.5-meters access aisle?
Yes


Is there a 2.5 meters wide space with minimum 2.5 meters wide access aisles and 2.5 meters of vertical clearance available for lift equipped vans?
No


Are the accessible aisles part of the route to the accessible entrance?
No


Is the accessible parking space marked (or painted on street) with the International symbol of accessibility? are these signs reading "van-accessible" at van signs?
No


Is there an enforcement procedure to ensure that accessible parking is used only by those who need it?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Is the route at least 0.9 m in width?
No


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
No


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No


Are all ramps longer than 2 meters have railings on both sides?
No


Is the width between railings or curbs at least 0.9 meters?
No


Are the railings sturdy and between 0.84 and 1 meters in height?
No


Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
No


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


If provided are carpeting or mats a maximum 1 cm height?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
No


If the door has a closer does it take at least 3 seconds to close?
Yes


Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
Yes


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
Yes


Is the text of the sign brailed of the same information?
No


If a pictogram is used is it accompanied by raised characters and braille?
No


Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes


Are they operable with a closed fist?
Yes


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes


Are the spaces for wheelchair distributed throughout?
Yes


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
Yes


Are there signs at inaccessible rest rooms that give directions to accessible ones?
No


Is the doorway at least 0.9 meters clear?
No


Can doors be opened easily (operable with closed fist)?
Yes


Is the toilet seat 0.43 to 0.48 meters high?
Yes


Is the toilet seat supported with a built-in bidet or does it have a handheld bidet?
Yes


Are the soap and hand dryers within reach ranges and usable with one closed fist?
Yes


Is the mirror mounted with the bottom edges of the reflecting surface 1.02 meters high or lower?
No


Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able

Subscribe to our newsletter and don’t miss any updates